Transducer Simulator 4
• Designed for high accuracy
• Sealed lid with neoprene O-ring
• Dustproof and crush tested to 500 lb
• Four operational modes including vernier adjustment, calibrated adjustment, 0.25 mV/V offset and 0.50 mV/V offset
• Ideal for setpoint or batching simulation
- Descripción
Descripción
Range:
Choose any fixed setting ± 0.25 mV or 0.50 mV through a 10-turn wire-wound potentiometer with locking clutch, fixed and variable
Maximum Voltage:
15 V
Linearity:
Less than ± 0.02% full scale
Temperature Coefficient:
Absolute 5 ppm/°C; Tracking less than 0.5 ppm/°C
Load Factors:
Simulates 1, 2, 3, 4 or 8 350-ohm load cells or 2, 4, 6, 8 or 16 700-ohm load cells
Offset:
+0.25mV/V for use with digitally calibrated meters requiring positive dead load for calibration
Connectors:
Six-way binding posts, suitable for loose wires or banana jacks
Warranty: