DLR334/DLR3110 Digital Pressure Indicator

  • 115 or 230 VAC operation
  • Ranges from vacuum to 10,000 psi
  • 20 selectable engineering units
  • Freeze mode for pressure switch testing
  • 0.05% of reading, 0.1% of reading or the economical 0.25% of reading model
  • Selectable resolution
  • Digital outputs: RS-232, RS-422 and RS-485
  • Min/Max pressure readings
  • Accuracy is percent of reading from 20% of F.S.
  • Different technicians can operate the unit and get identical results
  • Gases or fluids compatible with 17-4PH or 15-5PH may be used
  • Calibration certificate included; traceable to the National Institute of Standards and Technology(NIST)
Cotizar por whatsapp

Overall Accuracy:
0.05% of reading, 0.1% of reading, 0.25% of reading all from 20% of full scale and above. Below 20% of full scale units remain 0.05%, 0.1%, or 0.25% of 20% of full scale range. Includes all effects of linearity, hysteresis, repeatability, and ambient temperature. No temperature effect from 40°F to 140°F. NIST traceable

Temperature Range:
Operating: 40°F to 140°F (4°C to 60°C)
Storage: 0°F to 185°F (-17°C to 85°C)
Warm up: 3 minutes to rated accuracy, 15 minutes to complete stability

Calibration:
Full NIST traceability. Calibration points can be adjustable for operator convenience. Calibration via front panel and/or digital interface

Resolution:
Adjustable, 50,000 display counts (maximum) of range

Display Size:
Two-line, six-digit, 0.6 in. high numeric display, eight alpha characters per line, three annunciator light bars, bright red Light Emitting Diode (LED)

Display Update:
Adjustable, 100 ms maximum

Media Compatibility:
Any media compatible with 17-4PH or 15-5PH stainless steel

Overpressure:
200% of range (minimum)

Power Requirements:
115 or 230 VAC

Case Material:
Single piece extruded aluminum or panel mount sheet metal

Weight:
DLR334 Table top: 7.5 lb (3.4 kg)
DLR334 Panel mount or table top: 8.7 lb (3.9 kg)

Overall Accuracy:
0.05% of reading, 0.1% of reading, 0.25% of reading all from 20% of full scale and above. Below 20% of full scale units remain 0.05%, 0.1%, or 0.25% of 20% of full scale range. Includes all effects of linearity, hysteresis, repeatability, and ambient temperature. No temperature effect from 40°F to 140°F. NIST traceable

Temperature Range:
Operating: 40°F to 140°F (4°C to 60°C)
Storage: 0°F to 185°F (-17°C to 85°C)
Warm up: 3 minutes to rated accuracy, 15 minutes to complete stability

Calibration:
Full NIST traceability. Calibration points can be adjustable for operator convenience. Calibration via front panel and/or digital interface

Resolution:
Adjustable, 50,000 display counts (maximum) of range

Display Size:
Two-line, six-digit, 0.6 in. high numeric display, eight alpha characters per line, three annunciator light bars, bright red Light Emitting Diode (LED)

Pressure Hose:
Quantity supplied: One output
Length: 4 ft. nominal

Display Update:
Adjustable, 100 ms maximum

Media Compatibility:
Any media compatible with 17-4PH or 15-5PH stainless steel

Overpressure:
200% of range (minimum)

Power Requirements:
115 or 230 VAC

Case Material:
16 gauge, mild steel with textured finish, baked epoxy enamel paint

Weight:
DLR3110: 19 lb (8.6 kg)

Overall Dimensions:
19 W x 7 H (EIA 4U) x 10 in. deep (482.6 W x 177.8 H (4 HE) x 254 mm) Excluding front handles