DeviceNet® Interface
- DeviceNet communication adapter
- DIN-rail mount for installation with 880
- Compact size for internal installation in 720, 820i and 920i® indicators
- Polled I/O connection
- 125 Kbps, 250 Kbps, and 500 Kbps baud rate
- On-board LED diagnostics
- Floating-point commands support decimal points
- Descripción
Descripción
Power Requirements:
Bus adapter card with DeviceNet Module, DC power
Supply voltage 6 VDC, supplied by 720i, 820i and 920i bus
Typical current draw: 270 mA
Power consumption: 1.62 W
The bus shall be supplied with 24 V DC
±10% on the fieldbus connector
Field Bus Interface:
Pluggable screw connector
Operating Temperature:
14°F to 104°F (-10°C to 40°C)
Diagnostic Led:
Network status, module status
Communications:
Twisted-pair cabling at 125, 250, or 500 Kbps
Update rate is dependent on the configured baud rate and the number of network modes
Galvanic Isolation:
Bus power is separated from other electronics via DC/DC converter. The send and receive signals are isolated via opto couplers
Warranty:
One-year limited warranty